来自主题: Living版 - 有人用Lennox G71MPP的furnace吗?
does your furnace have air-intake pipe from outside? (Your high-efficiency
furnace should have two pipes: one is for vent; the other is for fresh air
intake. I guess that your contractor did cheap way, did not install intake
air pipe.
l******i
发帖数: 48
2
60-65F should be fine, make sure to close all the windows to preserve
temperature.
Also, switch on the faucets (especially those that connect to pipes in the
walls facing outside) to let it drip-this way the water inside the pipe is
slowly flowing and thus won't burst pipe because of cold weather.
j******r
发帖数: 855
3
来自主题: Living版 - 请问是哪儿漏水啦? 请谁来修?
Seems I still have a shot for thick wax ring.
The pipe is connected to the sink in the restroom too, I fill the sink and
then let the water run down through the pipe several times and no leaking.
the water just cover the bottom of the pipe when running, this may be
difference, water run down from toilet bowl is quick and with high volume.

ring.
v********e
发帖数: 1985
4
You better do some research.
http://starcraftcustombuilders.com/sources.faucets1.htm
http://starcraftcustombuilders.com/sources.faucets2.htm
Copied some text from the page, the subsection of lead in brass.
Most faucets are brass, and brass is a metal alloy that contains lead. As
of 1998, brass in faucets may contain up to 8% lead and still be labeled "
lead free" as long as they leach not more than 11 parts per billion (11 ppb)
into drinking water. However, the process used to test leaching deve... 阅读全帖
p***w
发帖数: 1906
5
05年的房子,这是卖家提供的前一个买家做的inspection(说是最后因为贷款的原因没买
成)我们自己还没做,想让版上大牛们帮忙看看有没有大问题,能下OFFER不?非常感谢
I. Structural Systems
A. Roof Covering Materials
^: The flashing is lifted under the window on the left roof slope. Nails
tend to back out over time,secure lifted flashing as needed.
X: Cap observed on plumbing vent pipe at roof level above master bedroom.
Vents pipes should be open so waste lines drain
properly and to vent sewer gases to the exterior. Consult qualified plumber
or roofer for evaluation to ens... 阅读全帖
m******9
发帖数: 968
6
是指sprinkler system的pipe吗? 如果阀门是好的,即使sprinkler pipe或者head有
破损也不应该持续漏水的,我家每天自动喷水10分钟,其他时间valve都是关闭的,应
该不会往pipe里供水。
难道是地下总进水管或者总出水管漏水了?
D*******a
发帖数: 207
7
来自主题: Living版 - 手工挖土2000CUFT,实例

好问题。交待一下:在我挖好沟之后,其实footer那里有以前的drain,不是管子,就
只是鹅卵石。我查过code,如果土质排水性好,那么鹅卵石的drain是可以的。我挖掉
了原来的鹅卵石(因为混了土,而且也不够多),铺透水布;填新的鹅卵石,然后是
drain pipe,然后又是鹅卵石,上面透水布再卷包起来。
问题是我的drain pipe要drain到哪里去?我做了两面墙,还有一面墙以后做;这已经
做的墙和以后做的墙的交界处是最低的地方;按照code要求,footer dain要么drain
to day light(自流出地面),要么连去city rain drain,要么在离房子N feet更远
处(N忘记了,可能是10)造一个旱井用来渗水,或者是sump pump。我因为还有一面墙
没做,所以我新安装的pipe就在两面墙交界处终止在原来的鹅卵石里。原来的鹅卵石是
不是继续走到city drain我就不知道了。计划是下一步继续做最后一面墙(总共就三面
),然后看情况,是挖旱井,还是顺藤摸瓜看原来的drain到何处去,还没有进行计划
。可能会安排个sump pump,室外的。
现... 阅读全帖
s******t
发帖数: 1956
8

the pipes are plumbing venting system. For water to drain freely out of a
house waste system, there must be adequate venting. The venting performs
three functions. It allows air in front of the water rushing through the
waste pipe to be
pushed out of the way, and it also allows air to be reintroduced to the
waste piping after the water has gone by. Lastly, it allows sewer gases
to escape outside through a vent stack.
a**r
发帖数: 661
9
来自主题: Living版 - [合集] 手工挖土2000CUFT,实例
☆─────────────────────────────────────☆
Dannemora (Dannemora) 于 (Wed Aug 29 22:41:07 2012, 美东) 提到:
第一段:挖深8FT,上口宽2FT-4FT不等,底宽1.5-2FT,长75FT。至少1200CUFT。
第二段:挖深2FT,宽1.5FT,长50FT。可能150CUFT。
绝大部分是巨石+粘土+砂质土。最大的巨石是500LB,砸不开;3-400LB的数个,能砸开。
☆─────────────────────────────────────☆
zoun (zoun) 于 (Wed Aug 29 22:47:24 2012, 美东) 提到:
这是玩命啊,土塌下来十条命都没了,赶紧上支架,不是吓你的。
☆─────────────────────────────────────☆
Dannemora (Dannemora) 于 (Wed Aug 29 22:58:02 2012, 美东) 提到:
塌方好几次了,都是下雨的时候塌的。所以上口才宽。上口宽了就不塌了。天气好... 阅读全帖
J**S
发帖数: 25790
10
来自主题: Living版 - 请教DIY高手
是啊,我想也是。但是看YOUTUBE,比如ISLAND的RANG HOOD,只看他们在天花板打洞,
然后把HOOD装上,没见到弄长PIPE到屋顶。 还有,有的RANG HOOD没有VENT PIPE,居
然就在CABINET的下面打个洞,下面是RANG HOOD,HOOD里有FILTER就完事了。
所以我奇怪,才想,是不是,不一定要有VENT PIPE通屋外面。
j******8
发帖数: 1006
11
来自主题: Living版 - 包子问Attic空调机问题....
The box under the AC is the drain pan, just in case there is a leak the
water won't damage your ceiling.
The open PVC pipe most likely is the drain vent, don't cover it.
The other copper pipe (#1) is the refrigerant pipe, seems like is not well
insulated, just go to homedepot buy a piece 1/2" insulation to wrap it then
you won't see the condensate anymore.
c**i
发帖数: 27
12
来自主题: Living版 - 解答空调
请问imore一个空调出水的问题.
我家的空调工作的时候,2楼屋檐下有个pipe总是有很多水滴出来,空调运行一切都是正
常的. 空调的main unit是在楼下. 有朋友告诉我可能是空调的main pipe堵住了,所以
水从secondary pipe出来了. 想请问一下,这个大概是什么问题, 如果要维修的话,应该
做什么和大概费用是多少?
谢谢!
c**i
发帖数: 27
13
来自主题: Living版 - 解答空调
请问imore一个空调出水的问题.
我家的空调工作的时候,2楼屋檐下有个pipe总是有很多水滴出来,空调运行一切都是正
常的. 空调的main unit是在楼下. 有朋友告诉我可能是空调的main pipe堵住了,所以
水从secondary pipe出来了. 想请问一下,这个大概是什么问题, 如果要维修的话,应该
做什么和大概费用是多少?
谢谢!
a*****0
发帖数: 3319
14
来自主题: Living版 - washer/dryer装好了。
Thank you very much for sharing.
My contractor said the previous owner used electric dryer. So I asked him to
add a T-connector and install a gas pipe for my dryer.
I also need to buy exhaust pipe etc. May I ask where you got those? Do you
have a link or picture? I don't think we'll move current exhaust pipe to the
newly bought house.
Thank you very much.
a*******e
发帖数: 428
15
来自主题: Living版 - 这几个管是干什么
Here are some pictures of some pipes from my evaporator. I believe they are
for induction of condensation water. But, why are there two pipes? Two
layers of protection? In fact, there are three open pipe ends on the walls
of the house, each side one. So, what is the third one? Any idea?
s******t
发帖数: 1956
16
来自主题: Living版 - 厨房洗手盆堵了,求救
My tenants clogged the kitchen sink last week. We tried plunger and clog
remover first. Unsuccessful. I dissembled the pipes and found the clogged
point was somewhere in the pipe behind the wall. My tenants bought a snake
from HD. We tried to push the snake into the pipe several times and cleaned
the clog out finally.
x*******u
发帖数: 194
17
来自主题: Living版 - 要换中央空调了,求建议---急
Just got a quote from one of the vendor. Can anyone help to check and advise
if that is reasonable? Or need improvement. Thanks!
INSTALL NEW GAS FURNACE 80% 140BTU TRANE
NEW 4 TON AC COIL R410A TRANE
NEW 4 TON CONDENSER R410A 13 SEER TRANE
MATERIAL- ALL GAS PIPE AND FITTINGS, CONDENSATE DRAIN LINE
ALL COPPER FITTINGS AND PIPE, FLUE PIPE MATERIAL, MODIFICATION
OF DUCT WORK, NITROGEN TEST ON FREON LINES, VACUUM OF
Description
ESTIMATE: REPLACE EXISTING FURNACE AND AC SYSTEM
REMOVAL OF EXISTING FUR... 阅读全帖
x*******u
发帖数: 194
18
来自主题: Living版 - 要换中央空调了,求建议---急
Many thanks!Will have Baozi delivered later.
Had another one with one additional humidifier. Please also advise. We will
make decision before this weekend and start installation by Monday.
ESTIMATE: REPLACE EXISTING FURNACE AND AC SYSTEM
REMOVAL OF EXISTING FURNACE, AC COIL, AND 4 TON
CONDENSER
INSTALL NEW GAS FURNACE HIGH EFFICIENT
NEW 4 TON AC COIL R410A
NEW 4 TON CONDENSER R410A
TRANE XR 95 FURNACE 120 BTU/ MODEL#- tuh1d120a9601a
TRANE 16 SEER 4 TON CONDENSER -m#- 4ttr5049e10000a
AC COIL 4 TO... 阅读全帖
x*******u
发帖数: 194
19
来自主题: Living版 - 要换中央空调了,求建议---急
Many thanks!Will have Baozi delivered later.
Had another one with one additional humidifier. Please also advise. We will
make decision before this weekend and start installation by Monday.
ESTIMATE: REPLACE EXISTING FURNACE AND AC SYSTEM
REMOVAL OF EXISTING FURNACE, AC COIL, AND 4 TON
CONDENSER
INSTALL NEW GAS FURNACE HIGH EFFICIENT
NEW 4 TON AC COIL R410A
NEW 4 TON CONDENSER R410A
TRANE XR 95 FURNACE 120 BTU/ MODEL#- tuh1d120a9601a
TRANE 16 SEER 4 TON CONDENSER -m#- 4ttr5049e10000a
AC COIL 4 TO... 阅读全帖
H**E
发帖数: 620
20
we're having the similar problem too.... a big headache.....
from my research on previous posts it seems the only ways are:
1. rout the vent pipe through top portions of the kitchen cabinets, which
will take some cabinets room...
2. rout the vent pipe on top the cabinets and add some dry wall to cover it.
which seems having more installation work and may impact house value ?
..
is it possible to hide the vent pipes into the ceiling ?? does anyone know
usually how much space between the ceiling... 阅读全帖
b*****g
发帖数: 2727
21
赞。
补充一下:如果有像我家一样只有garden hose connector的,要买3/4 garden hose
thread (GHT)的,要买GHT (MHT-Male HT or FHT-Female HT)到National Pipe Thread
(NPT, or MIP-Male Iron Pipe or FIP-Female Iron Pipe)的转换。因为compressor
上的Quick Connect一般是转到1/4 MIP的。
我没找到3/4 GHT到1/4 MIP的adapter,只好 3/4 GHT -> 1/2 NPT -> 1/4 NPT ->
Quick Connect
还有就是买的时候MIP/FIP的1/4inch不要和OD/ID 1/4英寸混淆。
z*******a
发帖数: 44
22
来自主题: Living版 - 这个钱该不该付
出租的房子,厕所水池漏水。我去看了一下,如果只是开着水龙头是不漏的,但要是先
攒满水,让水一下子冲下去,就会漏的很明显。
我找了个plumber,今天上午去搞。我有事,所以都是我老婆和他交涉的。他和我老婆
说sink不漏,是下面的管子漏,搞一下207。说是有warranty,再漏免费来修,所以不
需要担心。我老婆也不懂plumbing,就让他修了。
这哥们换了pipe后,终于承认sink也漏了,说是要换sink,200 labor再加材料费。我
老婆问他不是207管修好,还有warranty吗。他说pipe是修好了,也不漏了,你这sink
是新地方,得另外给钱。
我觉得他就是骗我老婆啊,207换个pipe,这个要这么贵吗,我在家都是自己换的,很
简单啊,就是塑料管子拧一拧。而且我去看的时候没看到管子漏水啊。漏的水池根本没
修啊。我们叫他走了,太不靠谱了。
这个207该不该付啊,不付会怎么样
l**********g
发帖数: 426
23
If the water was shut off and drained, there could be no damage at all. If
Water was left in the pipes, many pipes might have broken. It might cost $
500 per leak to open the wall or ceiling and patch a simple leak. Patching
and painting would be extra, and would be your responsibility. The piping
will probably be copper, because it looks like it was built in 1972. They
would not fail because of rust. If the water heater is broken or not
working, you should figure $1500.00 to replace it, i... 阅读全帖
i***e
发帖数: 9429
24
来自主题: Living版 - DIY Water heater .

pipe
before
gas flex pipe 越短越好,通常是装在 gas shut off valve 和 water heater gas
valve 之间的如果local 允许用gas flex pipe。
至于你用在两根硬管之间做连接,我所居住的城市我知道是允许的,可不代表所有城市
都允许。
(如有类似装法的同学,最好问清楚在装。)。
x***1
发帖数: 312
25
来自主题: Living版 - 换热水锅炉,plumber要900刀
Here's what else we found:
Water runs hot and cold
Manufacturers of tankless water heaters are fond of touting their products'
ability to provide an endless amount of hot water. But inconsistent water
temperatures were a common complaint among our poll respondents. When you
turn on the faucet, tankless models feed in some cold water to gauge how big
a temperature rise is needed. If there's cool water lingering in your pipes
, you'll receive a momentary "cold-water sandwich" between the old and n... 阅读全帖
b********t
发帖数: 1500
26
来自主题: Living版 - 请教换屋顶选哪个,多谢了
三家差不多吧,
但是第三家有指出前两家没有的东西,
装新的pipe boot, heavy duty drip edge还有new flashing where needed
但是他没有说如果换Deck 加多少钱, 这可能是个漏洞,
但是你屋顶状况不坏的话, 可能不用花这个钱,
第二家有指出加铺diamond deck underlayment,
楼主是在北方吧 所以要铺六呎以上的ice guard,
其他的部分就要铺这个underlayment or felt paper
假设第一家和第三家会装一般的felt paper这个上就有价差
SingleVent II 是个知名牌子, 其他两家没有指名, 也要问一下,
不过我猜想第一家和第二家都是同样牌子的厂商,
我觉得最重要要问清楚, 他们怎么处理pipe boots建议是全部换新,
怎么做flashing. 屋顶上现有的pipe, vents 他们要怎么做防水
屋顶和烟囱 屋顶和siding 交界的地方 他们要怎么做flashing
在不替换gutter 的情况下, 怎么重做dripping edge,
你做了ridge vent 那S... 阅读全帖
u**m
发帖数: 372
27
来自主题: Living版 - sewer line jammed with roots
Thank you for all the replies. I will ask about hydrojet cleaning cost.
I am considering the following two options. Appreciate your suggestion!
1. We do not have a cleanout point, and the only main access is on the roof.
To help cleaning up the pipe, would you think adding a house cleanout
access point without changing the pipe be good enough? The cost is about 800
~1000.
2. Changing the pipe costs about $4500 including all permits and
installation of 2 cleanouts to the property line. Does that ... 阅读全帖
w*******g
发帖数: 9932
28
来自主题: Living版 - 换sump pump又奖问答
I replaced a battery backup before and is pretty easy. just follow the same
pattern and use new pcv pipe. you need to get primer and PVC cement to
connect pipe and may need to cut pipe to fit. check valve does not matter
too much since the backup is rarely activated
sump pit cover need to be sealed with caulk which is a pain in the ass
suggest marine battery for backup.
don't use battery that needs to add water. it's a super pain in the ass to
maintain. be careful with the battery charger. some ... 阅读全帖
h******n
发帖数: 2795
29
除非是房屋周边有大树,会因为树叶掉进downspout而阻塞storm pipe。
其实,最容易引起storm pipe阻塞的恐怕是屋顶材料Asphalt shingles中像沙子一样的
东西,通过gutter到downspout,掉落到storm pipe。
过滤网对这类沙子一样的物质无法过滤。
h******n
发帖数: 2795
30
跟浴缸和马桶没有太多关系,是你家的下水道(Sanitary pipe)堵住了.通常的做法是
:用Snake疏通Sanitary Pipe直到与公共Sanitary Pipe交汇的地方。
需要疏通好几次才能清理掉堵塞的毛发,卫生纸等用品。
Youtube有相关视频,看几遍相关视频后,跟Plumber沟通一下,在疏通过程中,提出你
自己的建议。
x****u
发帖数: 12955
31

You do realize there is only maybe 1-2 feet of space between the ceiling
drywall and the subfloor on 2nd floor, don't you? How are you going to
stick a hard pipe into that space if you don't cut open a considerable sized
hole on the ceiling? Howe are you going to install support brackets along
the way, seal the connections between pipe segments, and seal the space
between pipe and wall without cutting access holes along the route?
x****u
发帖数: 12955
32

Then your installer probably did it wrong.
If he only cut one hole above your island, one hole on the wall, and somehow
he could route a pipe between the two holes, then unless it was a very
short run, he must have used flexible pipes.
Flexible pipes should not be used for range hood exhaust. Not only are they
inefficient for the purpose, but they would eventually crack and leak, and
you would then have a mess on your hand.
t******w
发帖数: 225
33
向大家求助
和老婆看了快4个月的房子,好不容易看上了这个86年的房子(之前阴差阳错错过了2个
房子)
学区,大小,维护历史都很中意
直到看到disclosure,93年地下室漏过水
***********
Basement: Any leaks or evidence of moisture?
Yes.
Comments: Leak where water pipe entered house repaired in 1993.
***********
我们的代理从对方获得的信息如下:
The PVC pipe went into the house from outside between water meter is leaking
. The pipe was changed by WSSC back in 1993. Their agent said it was
completely fix and didn't find any leaking ever since.
***********
请问这个地下室漏水会很严重么?
我们的代理说做house inspection可以... 阅读全帖
t******w
发帖数: 225
34
向大家求助
和老婆看了快4个月的房子,好不容易看上了这个86年的房子(之前阴差阳错错过了2个
房子)
学区,大小,维护历史都很中意
直到看到disclosure,93年地下室漏过水
***********
Basement: Any leaks or evidence of moisture?
Yes.
Comments: Leak where water pipe entered house repaired in 1993.
***********
我们的代理从对方获得的信息如下:
The PVC pipe went into the house from outside between water meter is leaking
. The pipe was changed by WSSC back in 1993. Their agent said it was
completely fix and didn't find any leaking ever since.
***********
请问这个地下室漏水会很严重么?
我们的代理说做house inspection可以... 阅读全帖
x****u
发帖数: 12955
35

your local water utility should have the grains per gallon number. If you
use the whole house water softener, the gallons of water you use each day *
grains per gallon * 10-15 days = capacity needed for water softener.
installation is not hard if you understand how to work with water pipes.
you will need some planning to split the routing of pipes if you want
certain faucets to not use softened water. for example your bathroom cold
water faucets and toilets.
Under sink cabinet may not be big... 阅读全帖
y*********u
发帖数: 1015
36
时常看到版上的帖子抱怨夏天空调不制冷,这次终于轮到我家了。
在网上和这个版上看了不少帖子,感觉和我碰的问题都不是很一样。
6年旧的楼上独立空调,以下是我已经试过或确认过的:
1.室内风扇和温度控制和户外风扇都正常运转
2.condenser应该也正常运转,因为可以听到AC liquid line (细铜管)内冷却剂流动的
声音。
3.air filter已经换了新的,外面condenser也用水清洗过。
4.draining pipe已经用Clorox通过了,肯定没有堵上。
5.draining pan里有一点水,不多,感觉evaporator coil可能原先有点结冰,已经通
过停止空调再加吹风去除冰了。
6. Evaporator所在的box摸上去挺冷,也有冷风从缝隙里漏出来,感觉evaporator coil
还是在制冷的
7. Ac liquid line摸着挺冷,但是AC suction line (保温材料包着的粗铜管)和环境
温度一样,不冷。网上文章说这不正常, AC suction line应该是 cold to touch.
现在就是air vent出来的风就是室温,... 阅读全帖
c***i
发帖数: 278
37
刚买了43年旧的房子,目前有个还能工作的21年旧的gas furnace,地处中北部寒冷地
区,担心今年寒冬旧的furnace突然罢工,打算换一个,房子2层共2600sf。
目前就找了costco的,给了high和low efficiency 的两个方案,麻烦imore大神看看那
个比较合理,还有那些参数需要考虑的,有没有降价空间,谢谢。
第一个是SL280V 80% two stage最小的机子36A,报价是3900,除去costco15%折扣后价
格是3315
第二个是EL296V 96% two stage最小的机子36B,报价是4800,除去costco15%折扣后价
格是4080
(1)Lennox SL280UH070V36A 80% AFUE Gas Furnace
Limited Lifetime Heat Exchanger, 10 Year Parts, 1 Year Labor Warranty
Bid Includes: Removal/Disposal of Existing Furnace;
Connection to Existing Gas Piping... 阅读全帖
F***Q
发帖数: 6599
38

ok, here are my closing procedures. I live in MA, I close my poor mostly at
the end of Sep, although it could be sooner. My procedures apply to my in-
ground vinyl liner pool. I assume other types of pools are similar.
IMPORTANT: pool repairs are expensive! you have to be very careful, don't
rush, if you don't understand the steps, don't do it. you may ruin your pool
permanently!
In summary:
1. add 4 gal shock and 16 oz algeacide, and circulate
2. drain water to a few inches below the returning... 阅读全帖
h****a
发帖数: 188
39
非常感谢你的宝贵建议,我认为如果pipe里面有root说明肯定是有crack了。我们想了
解一下如果不replace pipe,一般得多久需要疏通一次管道,这样来看看换pipe的
investment值不值得。

sewer
will
from
g********3
发帖数: 1281
40
Just root invading is not that bad. All clay pipes have this issue. Read
reviews on amazon or HD on root killer, you would know more about this root
issue. However, clay pipes are fragile. If they collapse, you will have to
replace the whole thing. Replacing a small portion may not work, because it
could cause the whole pipe fall apart. They are brittle.
d********9
发帖数: 3927
41
来自主题: Living版 - 这 costco 的 boiler 报价怎么样?
Install a Lennox GWB8 125,000 BTU gas hot water boiler, remove old boilers,
all piping and wiring: $14600
costco cash card: 15%
costco executive membership rebate: 2%
Total: $14600*(1-15%-2%)= $12118
他应该不给我重新 pipe,就是和 boiler 连的那一小段 pipe 换掉。$12118 是不是太
贵了?
boiler 哪个 brand 性价比高?
谢谢大家
x**l
发帖数: 2337
42
他们的home warranty条款包括下面这段文字,是不是他们的home warranty只限于房子
里面?房子外面的管道系统不在参保之列呢?
此home warranty的范围之内?
LHW (Landmark Home Warranty) will repair or replace systems and appliances
mentioned as covered that:
a. ...
b. ...
c. Are properly installed and located within the perimeter of the
main foundation or detached garage, except those noted with an “*”.
我们的Landmark Home Warranty是value plan 有关PLUMBING的条款如下
Water Heaters (up to 70 gal., unlimited units)
Tankless Water Heaters
Plumbing Pipe Leaks
Drain Line St... 阅读全帖
m*******p
发帖数: 1978
43
hot water passing through pipe that is not well tightened. The pipe expands
and contracts, making noises against the floor or studs.
it is not a problem other than a bit annoying. it is hard/expensive to fix (
need to open drywall to tighten and insulate water pipes).
k********n
发帖数: 18523
44
For EPCM company such as FLR, KBR, CBI, JEC, Bechtel, Wally Parsons...
Chemical process engineer
Piping engineer/piping designer
Piping stress engineer
Electrical engineer
HVAC mechanical engineer
Civil/Structural engineer and designer
Procurement specialist (shopping equipment
Raw material, hardware, etc)
For Upstream such as XOM, SHELL, BP, COP
Plus the following extra:
petrolieum engineer
Chemical engineer
Reservoir Level Analyst
Geotechnologist
Mining engineer
All of them need Huge IT depart... 阅读全帖
m******u
发帖数: 12400
45
除了学员外,很多读者来邮件咨询怎样交易美股和外汇?所以推出这个系列和大家交流
,不再一一回复了,希望帮到有心人
本周交易结果,三胜
美股指数多仓交易 +600 pipes
EUR/USD空仓交易 +100 pipes
美股EMC多仓交易 +1.17%
具体执行的情况如下
一. Wall St. 30 期指的周交易计划:
本周一小幅高开,按交易计划16日entry at 17280,将止损位设定 17230;本周股指大
涨,周五早盘17880点平仓,赚600 pipes 。再次证实了有准备的交易计划可以跟随市
场给予的机会,得到大的收获。见图,体会交易的快乐:
Nov 21 w30.png
二. EUR/USD 指数周交易计划
按计划EUR/USD ,我们平台的15min chart 在16日10:30分出现做空信号 entry at 1.
0750 ;在1.0800做止损,由于60周期线没有显示趋势,所以17日在1.0650平仓,赚
100pipes。
三. 基于Wall St. 30指数同方向(做多或者做空)... 阅读全帖
e*****s
发帖数: 78
46
来自主题: Immigration版 - [已转让]转让审稿
转让审稿
Title: On Collapse of the Inner Pipe of a Pipe-in-pipe System under External
Pressure
Journal: Engineering Structures
If you are interested in reviewing the manuscript, please send the following
information to [email protected]:
You name, degree, organization, title, email address, and one sentence
introducing your background. Thanks.
c******7
发帖数: 2586
47
来自主题: Boston版 - Radon test 4.7
our reading was at 2.1 I think, basically 4.7 is right around the state
limit 4 pCi/L so you are not off too much.
If you still want this house 4.7 reading could force seller to spit out some
serious cashback, so make sure you leverage this. There are several ways to
lower your Radon readings:
A. Gas Permeable Layer
This layer is placed beneath the slab or flooring system to allow the soil
gas to move freely underneath the house. In many cases, the material used is
a 4-inch layer of clean g... 阅读全帖
w**********9
发帖数: 1098
48
只能给你一个购物指南,一百五有价无市。我每次都是磕头作揖师傅才愿意。七月份师
傅们都忙,无论大的小的。 我有一个客人找了师傅来估价,估完了说我没时间做。 俺
当时真想说,那你来干什么?人家后来回话:想做的话给排在两个月以外。后来只好等
着。问一个水工,能不能给拿个permit加个卫生间,人家说等冬天吧
为什么我当初没有去干装修啊。
一家之言,见笑
油烟机:
Ebay上面买,据说也是名牌,只是没有贴牌。
分两种:
装柜子下面的
http://www.ebay.com/itm/30-Stainless-Steel-Under-Cabinet-Range-
WALL MOUNTED 直接上墙的, 8'的Vent Pipe
http://www.ebay.com/itm/30-STAINLESS-STEEL-VERY-POWERFUL-WALL-M
一般家里的是30寸的,偶尔是36寸的,要和你的炉子一边长or bigger。以上链接仅供
参考,您自己再费心找找。
http://www.costco.com/Ancona-Chef-Under-Cabinet-II-Kitchen-Rang
th... 阅读全帖
j**d
发帖数: 293
49
我家里前两天也堵了,请plubmer修好了。第一个plumber告诉我地下的sewer pipe破了
,我一分钱没给他,因为不知道他说的是真是假,也没有给我fix;第二个plubmer是
angiest list上找的,评价很高,果然很快就发现问题,告诉我树根钻到sewer pipe里
了,说这是很常见的问题(我同事告诉我她家也有同样的问题),用一个带锯的snake
,把树根都锯掉,拖出来了。话了差不多400刀,但是至少问题解决了。告诉我以后可
以用chemical把pipe里的树根杀死。
f*******3
发帖数: 584
50
来自主题: NewJersey版 - water heater 的维修问题(有图片)
What is the water heater temperature setting? In normal temperature setting,
the air going through the vent (vent CO2 to roof) just warm air. But if it
set too high, the air going through the vent could be like "steam" of which
met the cold water pipe could condense to water in surround the cold water
pipe.
Also, if the temperature set too high, the hot water inside the heater could
boiling and escape out from the safety pipe (the one shown vertical to the
ground) and leak to the ground (steam q... 阅读全帖