w*******y 发帖数: 60932 | 1 TODAY ONLY
Intermatic Z-Wave Enabled In-Wall Receptacle:
http://www.priceplunge.com/
$12.99
Use code:RMN10 for 10% off. Shipping $2.99. Compare price to $24.40
DETAILS:
Plugging in and flipping a switch are last years methods of turning the
power on to your devices. Everything is wireless now from your phone, to
your network connection and even to your lamp. Why bother with a power
cord or button when you can turn on that light or small appliance remotely?
The Intermatic Z-Wave Wireless En... 阅读全帖 |
|
v********e 发帖数: 1985 | 2 http://www.home-inspectors.com/alumwire.htm
"Should I be concerned about a home containing Aluminium Wiring?"
ANSWER
Most electrical wire is made of copper. Copper is predominately used in
residential construction with the exception of the service cable and single
purpose high-amperage circuits such as sub-panels, electrical ranges or air
conditioners. Since copper is a better conductor than aluminum, the aluminum
wire must be larger to safely carry the same current as copper.
Some houses built ... 阅读全帖 |
|
|
i***e 发帖数: 9429 | 4
所谓的“IN”就是接入 GFCI Receptacle 的incoming 电源,通常Marked as “Line”
,见图,蓝色线。所谓的“Out”就是 经过 GFCI Receptacle, 再延伸到其它
Receptacles, 通常Marked as “Load”,见图,红色线。也就是通常说的一 拖二,一
拖三,这样的设置可节约些GFCI Receptacles 的钱。
当认为GFCI Receptacle 坏了,换之前,需要先确定有没有incoming 电到,见图GFCI1
只有在 LINE Terminal 上有 125V 电源的情况下,而GFCI插座reset后不起作用或无法
reset, 那么换新的就可以了。换时关掉相应的circuit breaker. |
|
s*******y 发帖数: 136 | 5 Water Control System
10. The gutter is damaged at the front upper right.
Debris is present in the gutter and downspout systems. Debris build-up will
hinder
adequate water flow. As a result, water can build-up and exit the gutter
system
prematurely, drain down the siding and collect near the foundation walls.
This condition is
conducive to moisture intrusion.
Remove the debris from the gutter system to allow for adequate roof water
drainage and $400 to $700
repair or replace the affected gutters ... 阅读全帖 |
|
f*********s 发帖数: 1881 | 6 今天基本上完成了主卧,中间出了一点波折,不然只需要半天就够了。
花了大概一个小时的时间在房间里用stud finder找stud,并且不时上attic去看看对应
的障碍物,然后拟出几种方案给LD最后拍板。最后决定在Heating管道的内侧装4盏。具
体过程是用一枚长钉穿透ceiling,然后到顶上看误差,实际上在底下测量的点通常都
和预想的点是一样的。接着下来用hole saw锯圆孔,用recessed light housing校正。
这些实际上上午就完成了,下午就是波折的一下午。
由于这个房间之前并没有装灯,所以没法借用天上的线路,所幸有个receptacle
switch,所以可以借用这个开关盒,不用再在墙上开洞。原计划在顶上钻个洞,然后用
fishing tape钻进开关盒,结果在顶上对应的位置发现已经有一黑一白两根线走出来,
而且其中白的那根正好是通向receptacle switch控制的outlet,大喜过望,就把这条
白线切断,直接连上第一个灯。结果马上发现搞错了,因为虽然灯马上就亮了,但是不
能由开关控制,只有上去把那条白线重新接回去。(一直到最后都没搞清这个白线是干... 阅读全帖 |
|
n*******w 发帖数: 6708 | 7 一直比较忙,没时间照照片
虽然漏水, 但是还能用,真的是懒得邮回去换
customer review 里关于leak 说了一大堆
但到现在我都不知道怎么弄出他们说的那个 loud snap
http://www.amazon.com/Hoover-SteamVac-Carpet-Cleaner-F5914-900/
If your new machine LEAKS, see note #2 below. I am just amazed at how many
people write that their machine leaked from day one, and they returned it.
It will leak if you skip a crucial one-time set-up step.
Paid $170 at Best Buy. This is my first carpet cleaner so I have nothing to
compare it to except my own expectations. Even though the ... 阅读全帖 |
|
l*******e 发帖数: 31 | 8 头脑发热从国内买了个豆浆机,到了美国用不了,功率大的变压器贵的都可以再买个豆
浆机了。刚好在商店看到有卖250V receptacle。是不是把家里的125V receptacle换成
这个就可以用了?功率上应该可以满足需要吧?
另外,商店里250V 的都是single receptacle,但是家里几乎都是duplex receptacle
,不知道能不能换,是不是还要自己走线?如果太麻烦或者造价太高就算了。请这里的
牛人指点。谢谢! |
|
p***e 发帖数: 472 | 9 Guess you want to use the 110V power to supply a 220V 豆浆机.
The receptacle won't help. It's not the receptacle, but rather the 豆浆机
itself needs a 220V input so that it can get to the rated power (功率)。
Just replacing the receptacle won't change the power supply from the outlet
(墙上插座) .
receptacle |
|
g****b 发帖数: 143 | 10 3.ELECTRICAL WORK $1354
a. Dedicated circuit for D/W, Ref., disposal, rangehood & outlets
b. Replace existing receptacle with GFI receptacle to code specs
c. Dedicated circuit for GFI receptacle to code specs
d. New outlet tied to existing circuit to code specs
e. Replace existing recept/switch
f. New switch on circuit (Disposal)
g. Replace existing surface mount l |
|
M*****u 发帖数: 144 | 11 一个几万块的小condo,现在检查报告出来了。请大家帮我看看有没什么问题。计划居
住2-3年。
我现在最大的concern就三条:
1. Water penetration behind guest bath room.
卫生间漏水,房间里没有事情,但是一使用就漏到外面走廊上去了。
我的comment: Please fix it and provide licensed plumber receipt and
warranty
.
2. Water leakage under bath sink and evidence of water penetration on
exterior wall and entry.
卫生间的洗手盆下面滴水,这个问题不是很大,但是结合上一条看,觉得还是要修修,
因为不知道问题究竟是哪里。
我的comment: Please fix it and provide licensed plumber receipt and
warranty
.
3. No water for the dishwasher.
据说是没有接上connection,只是新... 阅读全帖 |
|
J**S 发帖数: 25790 | 12 这是REPORT。
Some wall receptacles are of older 2-
prong, non-grounded type and were therefore not tested. Various 3-prong wall
receptacles are
not grounded. It appears these newer receptacles may have been connected to
the old 2-wire
cable. Therefore, the grounding slot is not operable on these outlets; this
is not proper but is
commonly done for practical reasons. Some outlets are grounded. |
|
g********3 发帖数: 1281 | 13 Get this and test whether one wire in the switch is alive. The detector will
beep is the hot wire is good (alive). If yes, check the receptacle where
the disposal plugs into. If it beeps again, the wire is fine. Change
receptacle. If not, the wire between the switch and receptacle is probably
bad.
http://www.lowes.com/pd_464286-295-40110N_0__?productId=5012972 |
|
V********6 发帖数: 593 | 14 1.1 Repair loose rail at the left side of the porch steps.
1.2 Repair the moisture damaged trim at the bottom left side of the wall.
2.1 Exterior windows-Repair the open seams visible between the siding and
aluminum clad material on the window at the rear of the 2nd floor & attic
by a qualified siding contractor to eliminate water entry and limit water
entry and subsequent moisture related damage over time.
3.1 Secure loose gutter (above porch stairs) to limit storm water runoff
onto th... 阅读全帖 |
|
s**a 发帖数: 1995 | 15 我准备在drywall 上面装两个power receptacle,一上一下,drywall背后走一条电源线
,把这两个power receptacle接起来。听说这要查building code, 看是否违反安全条
例什么的是吗?谢谢 |
|
a****t 发帖数: 1056 | 16 我们家给basement receptacles配的电流只有15安培,也就是说最多只能用15*110=1650
瓦特的电器, 如果我在下面装上个2000瓦特的电器,会不会
烧掉,能不能自己把配电间的circuit breaker 控制地下室 receptacles 的换成30安培
的? 电线应该够粗, 只是前任屋主没有充分利用地下室.
谢谢. |
|
|
f********t 发帖数: 382 | 18 谢谢,家里没有测电压的仪器,我准备去买。
我一直纳闷的是,台灯测试结果显示的是排风扇的电源插座没有电,那为什么排风扇的
电机会hum,hum的响呐? 那声音就像是disposal 堵了的声音。
今天还打了排风扇的厂家的技术支持电话,那人告诉我说这种情况是排风扇的电源插座
(receptacle) 坏了,应该换receptacle. 我也搞不清楚他说的对否,大侠们觉得咋样?
请指教,谢谢。 |
|
C**J 发帖数: 20 | 19 I planned to do the same job for my garage door opener using wire cover and
add a receptacle on the surface of ceiling.
http://www.homedepot.com/s/wire%2520cover?NCNI-5.
If your light is a recess light, or you need a better looking ceiling, guess
you have to do a real job, cut drywall, drill holes to add a new receptacle
box. I saw people did it. Don't put projector too close to light, heat may
damage it. |
|
|
J*********2 发帖数: 351 | 21 我室内装了2个 cloud camera
室外的我买了2个比你这个更清晰 视角更大的 但是后来我都退掉了 觉得不是太实用
主要是 视角再大 180度侧面还是会有盲点 如果人家从你180度侧面过来,电源一切
你啥都录不下来 而且如果不是杀手 是来偷你摄像头的 他妈的丢了你上哪找去?
警察才不会管你这种小事
还有连接电源线非常的challenge
我家如果全cover 前面要至少要2个摄像头 后院至少3个
我家outdoor receptacle只有1个在后院 摄像头的电源线都不够长 至少要再装4个
receptacle 这个也挺麻烦 |
|
J*********2 发帖数: 351 | 22 我室内装了2个 cloud camera
室外的我买了2个比你这个更清晰 视角更大的 但是后来我都退掉了 觉得不是太实用
主要是 视角再大 180度侧面还是会有盲点 如果人家从你180度侧面过来,电源一切
你啥都录不下来 而且如果不是杀手 是来偷你摄像头的 他妈的丢了你上哪找去?
警察才不会管你这种小事
还有连接电源线非常的challenge
我家如果全cover 前面要至少要2个摄像头 后院至少3个
我家outdoor receptacle只有1个在后院 摄像头的电源线都不够长 至少要再装4个
receptacle 这个也挺麻烦 |
|
i****r 发帖数: 1797 | 23 安装trolling motor receptacle遇到一个问题:
这个receptacle是三根线的,除了正负极外,还有一个大概是地线?这3根线怎么跟电
源相连呢?
同样的,在trolling motor端,那个插头3根线怎么跟motor的两根线连接啊?
各位大牛小牛们都来说说。。。 |
|
o*****s 发帖数: 1445 | 24 The Tesla Roadster uses a proprietary charging connector, although Tesla
sells a mobile adapter that enables recharging with an SAE J1772-2009
connector.[118] The vehicle can be recharged using:[119]
A wall-mounted 208–240 V, 70 A maximum current Home Connector. This appears
to be an OEM version of the TS-70 charging station from ClipperCreek.[120]
A portable 120–240 V, 40 A maximum current Universal Mobile Connector cable
that can plug into a NEMA 14-50 receptacle and other 240V receptacles usi... 阅读全帖 |
|
w********1 发帖数: 3492 | 25 Thu, 12 Jul 2012 13:28:41 PDT
A newly-published Apple patent application (via AppleInsider) reveals Apple'
s interest in exploring the use of the iPod nano's clip as a charging and
docking mechanism, a move that would eliminate the need for a dedicated
docking port on the bottom edge of the device as found in the current design.
By incorporating electrical contacts into the clip and using a dock adapter
to provide compatibility with Apple's current docking stations, the clamping
action of the iP... 阅读全帖 |
|
w****5 发帖数: 64 | 26 价格都是参照有执照的公司或者个人报价。我2,3年搜集的,现在世道不景气,应该可
以砍2~3成。(DC地区的价格,别的地方或高或低,就不清楚了。)贡献出来,希望对
大家有帮助。
Price ranges for common repairs/replacements in the home
The Cost ranges below are derived from nationally used repair cost guides
and are designed for budget purposes only. The costs reflect prices in
typical metropolitan areas. Your inspector recommends that you always
consult a licensed qualified contractor for repair options and costs for
major items as repair costs can vary widely dependant upon quality ... 阅读全帖 |
|
w*******y 发帖数: 60932 | 27 Link:
http://www.buy.com/prod/Ipowerpro-150w-Universal-Auto-Air-Adapter/q/loc/111/218202955.html
iPowerPro 150 Watt Universal Dual Voltage Auto / Airplane Adapter / Inverter
! Portable, compact dual voltage (100-120 VAC & 200-240 VAC) 150 Watt DC/AC
universal power inverter for notebook computers, pwersonal DVD players, and
other portable electronics. Specifications: Input Voltage Range: 11 ~ 15VDC.
Output Voltage & Frequency: US Receptacle 100 - 120 VAC 60Hz, Universal
Receptacle: 200 - 240 VAC... 阅读全帖 |
|
u***r 发帖数: 4825 | 28 http://online.wsj.com/article/SB1000142405274870447190457622801
* MARCH 28, 2011, 4:56 P.M. ET
By MITSURU OBE
TOKYO—Workers at Japan's damaged Fukushima Daiichi nuclear plant faced a
new threat Monday as they battled to keep toxic water from spilling into the
ocean, as the water's radiation levels offered the strongest sign yet that
the core of one reactor may have partially melted.
Also late Monday, plant operator Tokyo Electric Power Co. said that small
quantities of plutonium were detecte... 阅读全帖 |
|
i*****s 发帖数: 4596 | 29 OLD POISON JAR WAS CURLEY'S WEAPON
A WIFE'S CHANCE DISCOVERY OF THE
ARTIFACT FROM A FORMER STORE SPARKED
A MURDER PLOT THAT TOOK YEARS TO
UNRAVEL, A STATE TROOPER SAYS
By BONNIE ADAMS; Times Leader Staff Writer
Saturday, July 19, 1997 Page: 1A
WILKES-BARRE -- It began with a jar of rat poison from Joann Curley's
grandmother.
When Curley discovered the poison, she decided to use it to kill Robert
Curley for his money, state police Trooper Rob McBride said Friday, one day
after Curley admi... 阅读全帖 |
|
T**********e 发帖数: 29576 | 30
她是毕业生代表毕业典礼演讲。
By the time she graduated from Wellesley in May 1969, Hillary Rodham was
already such a notable figure that she was featured, along with four other
speakers from four other schools — and excerpts from their commencement
addresses — in the June 20, 1969, issue of LIFE, in an article titled,
simply, “The Class of ’69.”
1969 Student Commencement Speech
by Hillary D. Rodham (now Hillary Rodham Clinton)
May 31, 1969
Wellesley College
I am very glad that Miss Adams made it clear that w... 阅读全帖 |
|
M******a 发帖数: 6723 | 31 【 以下文字转载自 Mod_CHN_Hist 讨论区 】
发信人: Mayingba (吳鐘學), 信区: Mod_CHN_Hist
标 题: 奉天兵工厂
发信站: BBS 未名空间站 (Sun Jan 28 20:29:57 2018, 美东)
https://wwiiafterwwii.wordpress.com/2017/04/03/mukden-arsenal-after-wwii/
Mukden Arsenal after WWII
April 3, 2017 jwh19752 Comments
(Zhang's Gate, the old entrance to Mukden Arsenal)
For people interested in Japanese firearms of WWII, the name Mukden Arsenal
is familiar. The history of the facility after Japan's defeat is less well
known. Under various names, it did surv... 阅读全帖 |
|
发帖数: 1 | 32 这个应该好好查一下:
http://www.thegatewaypundit.com/2016/12/report-massive-nevada-voter-fraud-uncovered/
Barth interviewed Republican Assembly Candidate for District 15, Stan
Vaughan, who had actual proof of the massive voter fraud in his Clark County
district. A total number of 17,086 votes were cast in the District for
both Republican and Democrat candidates. However, when confirmation letters
were sent to the voters in the District, the US postal service returned mail
from 9,200 of these voters.
Vaug... 阅读全帖 |
|
d*****e 发帖数: 3868 | 33 usps first class parcel,给退回来了。 |
|
f****l 发帖数: 8042 | 34 前两天版上讨论CO detector的安装位置,有同学建议在有gas设备的房间,后来查了一
下CPSC的建议,发现完全不同,把网址和部分建议贴出来,share安全常识,大家居家
生活一切安全第一。
# How should I install a CO Alarm?
CO alarms should be installed according to the manufacturer's
instructions. CPSC recommends that one CO alarm be installed in the hallway
outside the bedrooms in each separate sleeping area of the home. CO alarms
may be installed into a plug-in receptacle or high on the wall. Hard wired
or plug-in CO alarms should have battery backup. Avoid locations that are |
|
O*******d 发帖数: 20343 | 35 In North America, regular residential houses are served with SINGLE PHASE,
CENTER TAPPED 120V/240V system. This system has 3 wires, two hot and one
neutral. The voltage between each hot wire and neutral wire is 120V. The
voltage between two hot wires are 240V. Most room receptacles are wired
between a hot wire and the neutral wire, providing 120V. Large electric
appliances, such as stove, oven, cloth dryer and central AC are using
electricity supplied from the two hot wires.
A 3 wire system |
|
|
|
H******7 发帖数: 34403 | 38 怎么又删了,不是说得很在理吗?
我觉得串联还是并联取决于receptacle内部两个螺栓间是怎么联法,这个从外面看不出
来 |
|
R********r 发帖数: 3415 | 39 You can do that, but you need figure it out where the junction box is
located. All the connection should be put inside.
In my case, after update, the receptacle is independent of the switch, the
switch only controls the lights. |
|
l***i 发帖数: 1943 | 40 新手买房子,seller发来了个他们做的inspection report,
看起来有些defect,急着要下offer了,
能请版上的牛人们帮忙分析一下那些是比较重要的问题么?
包子答谢!
defects:
1. Grading & Drainage
Comments: Observed soil / mulch too high in flower beds at rear of dwelling &
detached garage. Recommend repairs, establish proper drainage, and top soil /
mulch should be at least 2” below the siding or brick line and sloped away
from the foundation.
2. Roof Structure & Attic (If the attic is inaccessible, report the method
used to
inspect.)
Comments: Many areas of the ... 阅读全帖 |
|
m*f 发帖数: 8162 | 41 code规定countertop任何一点或左或右两英尺内有至少一个gfci receptacle,你挪掉
了很有可能就留出空白区域了。。。 |
|
w**5 发帖数: 316 | 42 可能GFCI Receptacle坏了。买一个换上。 |
|
J*********2 发帖数: 351 | 43 wait a minute. is just myself seeing this?
black is wired with white! something is not right.
this is bigger issue than the bad receptacle |
|
f*********s 发帖数: 1881 | 44 然后开始走线。还是和上个工作日一样,这个房间里有receptacle switch,省了不少
工作量,因为可以使用现成的线盒。简单来讲就是首先卸下crown molding,用水平仪
往线盒的上方延伸,在顶部钻连续的洞,一直往下,直到drywall,这样可以创造一个
从下往上的洞,比较利于fishing wire。 |
|
f*********s 发帖数: 1881 | 45 这是现有的线盒里面的线路情况,其中3条黑线揪成一团,很明显是这个线盒的供电来
源,另外一条孤零零的黑线就是通向receptacle switch控制的outlet了。 |
|
T*********n 发帖数: 804 | 46 都是细节,有点琐碎,有帮助的回复热包子答谢!
1. ceiling fan/light rough-in, $395
就是那种一进门旁边开关可以开天花板上的顶灯的选项,觉得中国人还是不喜欢落地灯
,大家会每个屋子都装吗?
2. recessed light or eyeball light with one switch, $200
这种屋顶的嵌灯呢?
3. Additional Electric receptacle, $90
这个是电插座吧,是不是车库,地下室,客厅应该要多装几个呢?万一要是以后装修地
下室,或者在车库做个项目什么的应该多些电插座吧。另外车库要不要加灯呢?
4. additional cable or phone outlet
这个是不是楼上楼下看电视都得要加cable的outlet。电话outlet的话是不是无所谓,
无绳电话整栋房子的coverage好吗?
5. garage door opener $795, extra transmitter $35
这个以后去HD买是不是会便宜一点?
新人毫无经验,先谢谢了! |
|
f****i 发帖数: 20252 | 47 Tamper-Resistant Receptacle
但是对拖线板无用 |
|