m***y 发帖数: 280 | 1 inspection的报告中这两处的情况比较差一些,请大家帮我看看这个问题是否很严重?
如果要换个
新的water heater 50 gallon的大概需要多少钱?1.cooling system(poor/defective
)
Desired temperature variance between supplly and return air is 15-
22degrees.Obtained 3 degrees at time of inspection.Supply temp=71 return
temp=74 outside temp=75
2.Water heater safety valve
provisions(poor/defective) The unit has insulation wrap installed and
this will prevent the safety relief valve from opening. Have wrap cut
away in the valve area. | t**m 发帖数: 263 | 2 water heater, 几百块
defective
【在 m***y 的大作中提到】 : inspection的报告中这两处的情况比较差一些,请大家帮我看看这个问题是否很严重? : 如果要换个 : 新的water heater 50 gallon的大概需要多少钱?1.cooling system(poor/defective : ) : Desired temperature variance between supplly and return air is 15- : 22degrees.Obtained 3 degrees at time of inspection.Supply temp=71 return : temp=74 outside temp=75 : 2.Water heater safety valve : provisions(poor/defective) The unit has insulation wrap installed and : this will prevent the safety relief valve from opening. Have wrap cut
| n****8 发帖数: 1716 | 3 1)这只能以后再查几次了。
2)关键是要拿掉insulation wrap才能知道里面到底是好事坏。要换新的可能要450料+
350工=800。
看样子这个inspection做得也不咋的。 | y*********u 发帖数: 1015 | |
|
|
|
|
|