i***a
发帖数: 195
1
废话少说,仅列事实而已:
1.辐射危害: 含辐射性元素的粉尘,经空气(主要)传播扩散后,人通过呼吸,皮肤接触,饮水等进入身体无法排解并常驻体内,这些放射性元素通过衰变产生粒子, 是危害人体细胞的罪魁祸首,而不是像在X光,CT检查中接受的粒子辐射,离开就没有了。这些进入人体的核粉尘的辐射危害是长期的。根据核电站中心的辐射水平,通过空气传播模型可以推算出扩散速度和辐射水平并,根据当地的辐射强度疏散受影响地区群众。如无法撤离,应呆在室内,避免接触空气和雨水。
2. 一回路驱动水泵:由于一回路水泵不工作(遭海啸,电力不足),反应堆内的一回路水循环中止,导致堆芯温度急剧上升,水在高温下变成水蒸气,最终导致燃料棒暴露于水面上。在高温高压下,一回路冷却水发生泄漏, 这时检测到辐射水平急剧上升。这是事故起因。
3.控制棒: 当控制棒(材料是硼或镉)插入燃料棒堆芯后, 吸收了大量慢中子使中子链式反应无法维持,从而使反应堆从(超)临界状态进入亚临界状态并最终停堆。但冷却过程很长,需要几天的时间。据信控制棒在发生事故时自动激活工作,但或许无法快速完全停堆,由于堆芯一回路失冷却水,导致温度急速上升。
4.H2产生并爆炸: 由于反应堆内高温高压下,包裹燃料的锆(Zr)在水中氧化,因此一回路内部分水变成氢气传统一级防护壳,排放到二级防护壳中,由于不断聚集产生在二级防护壳内产生高压,并最终和氧气发生反应造成了爆炸,摧毁了反应堆外面的二级防护壳。但是幸好保护堆芯的一级防护壳没有被摧毁,不过已经产生少量核泄漏,因为已经在核电站周围探测到大量放射性铯和放射性碘,如1.所言,这些放射性元素将被排放到空间造成核污染。
5.注入带硼海水: 为了使反应堆冷却,开始向堆芯一回路中注入掺有硼的海水,因为硼同位素(B10)具有强大的慢中子吸收截面(与控制棒作用一样),可以吸收堆芯内大量的慢中子,进一步降低俘获式核裂变的反应概率。这些海水注入堆芯后不会被排出回到海内,否则将大面积污染周围海洋环境。
6.堆芯防护壳:保护堆芯和核燃料的一级保护壳并未爆炸,目前的辐射来源于一级保护壳少量泄漏和二级保护壳中的旧燃料(spent fuel)泄漏,旧燃料存储于一级防护壳外二级防护壳内;由于旧燃料的辐射水平有限,因此目前来看核辐射污染并不严重。当然如果堆芯防护壳破坏,那么情况就非常严重了。现在看来发生这个情况的概率不是很大。
T****r
发帖数: 22092
2
简直是太out了。
掩耳盗铃有意思么?

【在 i***a 的大作中提到】
: 废话少说,仅列事实而已:
: 1.辐射危害: 含辐射性元素的粉尘,经空气(主要)传播扩散后,人通过呼吸,皮肤接触,饮水等进入身体无法排解并常驻体内,这些放射性元素通过衰变产生粒子, 是危害人体细胞的罪魁祸首,而不是像在X光,CT检查中接受的粒子辐射,离开就没有了。这些进入人体的核粉尘的辐射危害是长期的。根据核电站中心的辐射水平,通过空气传播模型可以推算出扩散速度和辐射水平并,根据当地的辐射强度疏散受影响地区群众。如无法撤离,应呆在室内,避免接触空气和雨水。
: 2. 一回路驱动水泵:由于一回路水泵不工作(遭海啸,电力不足),反应堆内的一回路水循环中止,导致堆芯温度急剧上升,水在高温下变成水蒸气,最终导致燃料棒暴露于水面上。在高温高压下,一回路冷却水发生泄漏, 这时检测到辐射水平急剧上升。这是事故起因。
: 3.控制棒: 当控制棒(材料是硼或镉)插入燃料棒堆芯后, 吸收了大量慢中子使中子链式反应无法维持,从而使反应堆从(超)临界状态进入亚临界状态并最终停堆。但冷却过程很长,需要几天的时间。据信控制棒在发生事故时自动激活工作,但或许无法快速完全停堆,由于堆芯一回路失冷却水,导致温度急速上升。
: 4.H2产生并爆炸: 由于反应堆内高温高压下,包裹燃料的锆(Zr)在水中氧化,因此一回路内部分水变成氢气传统一级防护壳,排放到二级防护壳中,由于不断聚集产生在二级防护壳内产生高压,并最终和氧气发生反应造成了爆炸,摧毁了反应堆外面的二级防护壳。但是幸好保护堆芯的一级防护壳没有被摧毁,不过已经产生少量核泄漏,因为已经在核电站周围探测到大量放射性铯和放射性碘,如1.所言,这些放射性元素将被排放到空间造成核污染。
: 5.注入带硼海水: 为了使反应堆冷却,开始向堆芯一回路中注入掺有硼的海水,因为硼同位素(B10)具有强大的慢中子吸收截面(与控制棒作用一样),可以吸收堆芯内大量的慢中子,进一步降低俘获式核裂变的反应概率。这些海水注入堆芯后不会被排出回到海内,否则将大面积污染周围海洋环境。
: 6.堆芯防护壳:保护堆芯和核燃料的一级保护壳并未爆炸,目前的辐射来源于一级保护壳少量泄漏和二级保护壳中的旧燃料(spent fuel)泄漏,旧燃料存储于一级防护壳外二级防护壳内;由于旧燃料的辐射水平有限,因此目前来看核辐射污染并不严重。当然如果堆芯防护壳破坏,那么情况就非常严重了。现在看来发生这个情况的概率不是很大。

i***a
发帖数: 195
3
你别回帖,这个不是写给你看的。

【在 T****r 的大作中提到】
: 简直是太out了。
: 掩耳盗铃有意思么?

n******t
发帖数: 1388
4
container of the reactor已经破损的话,又是怎样的情况?
j******h
发帖数: 3904
5
1漏了地下水的核污染
2错了
3动力操作的控制棒到位没有是个问题
4原因是燃料棒裂了,氢气爆了不会导致裂变气体泄漏,气态裂变产物是封在燃料棒内
的,如果燃料棒完好的话。
5和6就不说了
你别误导大家了
i***a
发帖数: 195
6
堆芯防护壳破损了,也意味着燃料棒也破损了,大量的放射性元素如铯和碘将随着高温
蒸汽冲入入空中随风传播,或会和水一起进入海洋。

【在 n******t 的大作中提到】
: container of the reactor已经破损的话,又是怎样的情况?
i***a
发帖数: 195
7
1.现在主要是靠空气传播,还没有轮到地下水呢。不提这个是因为还没有严重到这个地步
2.哪里错了?请指正
3.控制棒至少是工作了,否则堆芯必然融化,保护壳要爆炸。
4.氢气导致爆炸,使得二级保护壳破裂, 堆放在二级保护壳内的燃料泄漏,而且由于
一级保护壳也有少量泄漏(否则氢气无法进入二级保护壳内), 一级保护壳内本来就
存在大量放射性物质,随着氢气和水蒸气泄漏到二级保护壳内。当然也有可能是燃料棒
外层保护被融化了(参考2)。
5.6.都是事实。

【在 j******h 的大作中提到】
: 1漏了地下水的核污染
: 2错了
: 3动力操作的控制棒到位没有是个问题
: 4原因是燃料棒裂了,氢气爆了不会导致裂变气体泄漏,气态裂变产物是封在燃料棒内
: 的,如果燃料棒完好的话。
: 5和6就不说了
: 你别误导大家了

T****r
发帖数: 22092
8
看谁傻,写给谁看?

【在 i***a 的大作中提到】
: 你别回帖,这个不是写给你看的。
i***a
发帖数: 195
9
写给聪明人看,你太笨了,你看不懂的。

【在 T****r 的大作中提到】
: 看谁傻,写给谁看?
j******h
发帖数: 3904
10

地步
1.燃料棒已经出现破损,下一步就是融化如果水位下降得厉害的话,现在没人灌水放气
,弄不好把压力壳整个掀了都有可能。最后一步就是烧熔穿底,这个没学过,也不敢想
象。另外核废料污染了空气后降雨不就到地表了?水循环系统污染的后果。。。
2.沸水堆只有一个回路,冷却回路不算的。
3.可能没完全到位
4.燃料棒没破是不会有裂变产物泄漏到压力壳的。
5.你放蒸汽不一样是回到环境里,有什么区别?
6.请你说明什么是一级防护壳,是指燃料棒外壳还是?

【在 i***a 的大作中提到】
: 1.现在主要是靠空气传播,还没有轮到地下水呢。不提这个是因为还没有严重到这个地步
: 2.哪里错了?请指正
: 3.控制棒至少是工作了,否则堆芯必然融化,保护壳要爆炸。
: 4.氢气导致爆炸,使得二级保护壳破裂, 堆放在二级保护壳内的燃料泄漏,而且由于
: 一级保护壳也有少量泄漏(否则氢气无法进入二级保护壳内), 一级保护壳内本来就
: 存在大量放射性物质,随着氢气和水蒸气泄漏到二级保护壳内。当然也有可能是燃料棒
: 外层保护被融化了(参考2)。
: 5.6.都是事实。

T****r
发帖数: 22092
11
我确实是太笨了

【在 i***a 的大作中提到】
: 写给聪明人看,你太笨了,你看不懂的。
i***a
发帖数: 195
12
大家如果有兴趣,还是多看看美国原子能学会这样的专业机构对于该事故的情况报道,
别制造不必要的恐慌了。
http://ansnuclearcafe.org/
Japan Status Updates 02:00 GMT March 16, 2011
NUCLEAR ENERGY INSTITUTE UPDATE AS OF 01:00 GMT, MARCH 16
At 5:45 am, March 16, Japan Standard Time (4:45 pm EDT, 20:45 GMT, March 15)
, a fire reignited at Tokyo Electric Power Co.’s Fukushima Daiichi 4
reactor. The fire was extinguished after about two hours, TEPCO said.
TEPCO was planning to battle the fire and provide additional water to cool
used nuclear fuel with water dumped from helicopters, but abandoned the plan
because a hole in the building’s roof is not in close proximity of the
used fuel pool.
The company may remove some panels from the top of the reactor containment
buildings at reactors 5 and 6 in order to avert a possible buildup of
hydrogen in the reactors. Hydrogen buildup caused explosions at reactors 1
and 3.
All of the fuel rods had been moved from reactor 4 to the spent fuel pool
due to the maintenance work. About one-third of the fuel rods in reactors 5
and 6 had been removed as part of maintenance and refueling activities.
Seventy percent of the fuel rods Unit 1 and one-third in Unit 2 have been
damaged, TEPCO said. The cooling water level in both units is being
maintained.
Weather reports indicate that the wind at the Fukushima plant has shifted
and is now blowing out to the Pacific.
An earthquake registering 6.1 on the Richter scale struck the Eastern Honshu
region of Japan. Hamaoka nuclear plant, about 100 kilometers (62 miles)
from the epicenter, continues to operate normally.
NEW YORK TIMES March15, 2011 20:25 GMT
Workers strain to retake control after blast and fire at Japan plant
A small crew of technicians braved radiation and fire through the day on
Tuesday as they fought to prevent three nuclear reactors in northeastern
Japan from melting down and to stop storage pools loaded with spent uranium
fuel pods from bursting into flames.
Officials with the Tokyo Electric Power Company announced Tuesday evening
that they would consider using helicopters in an attempt to douse with cold
water a boiling rooftop storage pool for spent uranium fuel rods. The rods
are still radioactive and potentially as hot and dangerous as the fuel rods
inside the reactors if not kept submerged in water.
“The only ideas we have right now are using a helicopter to spray water
from above, or inject water from below,” a power company official said at a
news conference. “We believe action must be taken by tomorrow or the day
after.”
Hydrogen gas bubbling up from chemical reactions set off by the hot spent
fuel rods produced a powerful explosion on Tuesday morning that blew a 26-
foot-wide hole in the outer building of Reactor No. 4 at the Fukushima
Daiichi nuclear power plant. A fire there may have been caused by machine
oil in a nearby facility, inspectors from the United States Nuclear
Regulatory Commission said, according to an American official.
Concern remained high about the storage pools at that reactor and at two
other reactors, Nos. 5 and 6. None of those three reactors at the plant, 140
miles northeast of Tokyo, were operating on Friday afternoon when an
offshore earthquake with a magnitude now estimated at 9.0 suddenly shook the
site. A tsunami with waves up to 30 feet high rolled into the northeast
Japanese coastline minutes later, swamping the plant.
At least 750 workers evacuated on Tuesday morning after a separate explosion
ruptured the inner containment building at Reactor No. 2 at the Daiichi
plant, which was crippled by Friday’s earthquake and tsunami. The explosion
released a surge of radiation 800 times more intense than the recommended
hourly exposure limit in Japan.
But 50 workers stayed behind, a crew no larger than would be stationed at
the plant on a quiet spring day. Taking shelter when possible in the reactor
’s control room, which is heavily shielded from radiation, they struggled
through the morning and afternoon to keep hundreds of gallons of seawater a
minute flowing through temporary fire pumps into the three stricken reactors
, Nos. 1, 2 and 3, where overheated fuel rods continued to boil away the
water at a brisk pace.

接触,饮水等进入身体无法排解并常驻体内,这些放射性元素通过衰变产生粒子, 是
危害人体细胞的罪魁祸首,而不是像在X光,CT检查中接受的粒子辐射,离开就没有了
。这些进入人体的核粉尘的辐射危害是长期的。根据核电站中心的辐射水平,通过空气
传播模型可以推算出扩散速度和辐射水平并,根据当地的辐射强度疏散受影响地区群众
。如无法撤离,应呆在室内,避免接触空气和雨水。
回路水循环中止,导致堆芯温度急剧上升,水在高温下变成水蒸气,最终导致燃料棒暴
露于水面上。在高温高压下,一回路冷却水发生泄漏, 这时检测到辐射水平急剧上升
。这是事故起因。
子链式反应无法维持,从而使反应堆从(超)临界状态进入亚临界状态并最终停堆。但
冷却过程很长,需要几天的时间。据信控制棒在发生事故时自动激活工作,但或许无法
快速完全停堆,由于堆芯一回路失冷却水,导致温度急速上升。
此一回路内部分水变成氢气传统一级防护壳,排放到二级防护壳中,由于不断聚集产生
在二级防护壳内产生高压,并最终和氧气发生反应造成了爆炸,摧毁了反应堆外面的二
级防护壳。但是幸好保护堆芯的一级防护壳没有被摧毁,不过已经产生少量核泄漏,因
为已经在核电站周围探测到大量放射性铯和放射性碘,如1.所言,这些放射性元素将被
排放到空间造成核污染。
为硼同位素(B10)具有强大的慢中子吸收截面(与控制棒作用一样),可以吸收堆芯
内大量的慢中子,进一步降低俘获式核裂变的反应概率。这些海水注入堆芯后不会被排
出回到海内,否则将大面积污染周围海洋环境。
护壳少量泄漏和二级保护壳中的旧燃料(spent fuel)泄漏,旧燃料存储于一级防护壳外
二级防护壳内;由于旧燃料的辐射水平有限,因此目前来看核辐射污染并不严重。当然
如果堆芯防护壳破坏,那么情况就非常严重了。现在看来发生这个情况的概率不是很大。

【在 i***a 的大作中提到】
: 废话少说,仅列事实而已:
: 1.辐射危害: 含辐射性元素的粉尘,经空气(主要)传播扩散后,人通过呼吸,皮肤接触,饮水等进入身体无法排解并常驻体内,这些放射性元素通过衰变产生粒子, 是危害人体细胞的罪魁祸首,而不是像在X光,CT检查中接受的粒子辐射,离开就没有了。这些进入人体的核粉尘的辐射危害是长期的。根据核电站中心的辐射水平,通过空气传播模型可以推算出扩散速度和辐射水平并,根据当地的辐射强度疏散受影响地区群众。如无法撤离,应呆在室内,避免接触空气和雨水。
: 2. 一回路驱动水泵:由于一回路水泵不工作(遭海啸,电力不足),反应堆内的一回路水循环中止,导致堆芯温度急剧上升,水在高温下变成水蒸气,最终导致燃料棒暴露于水面上。在高温高压下,一回路冷却水发生泄漏, 这时检测到辐射水平急剧上升。这是事故起因。
: 3.控制棒: 当控制棒(材料是硼或镉)插入燃料棒堆芯后, 吸收了大量慢中子使中子链式反应无法维持,从而使反应堆从(超)临界状态进入亚临界状态并最终停堆。但冷却过程很长,需要几天的时间。据信控制棒在发生事故时自动激活工作,但或许无法快速完全停堆,由于堆芯一回路失冷却水,导致温度急速上升。
: 4.H2产生并爆炸: 由于反应堆内高温高压下,包裹燃料的锆(Zr)在水中氧化,因此一回路内部分水变成氢气传统一级防护壳,排放到二级防护壳中,由于不断聚集产生在二级防护壳内产生高压,并最终和氧气发生反应造成了爆炸,摧毁了反应堆外面的二级防护壳。但是幸好保护堆芯的一级防护壳没有被摧毁,不过已经产生少量核泄漏,因为已经在核电站周围探测到大量放射性铯和放射性碘,如1.所言,这些放射性元素将被排放到空间造成核污染。
: 5.注入带硼海水: 为了使反应堆冷却,开始向堆芯一回路中注入掺有硼的海水,因为硼同位素(B10)具有强大的慢中子吸收截面(与控制棒作用一样),可以吸收堆芯内大量的慢中子,进一步降低俘获式核裂变的反应概率。这些海水注入堆芯后不会被排出回到海内,否则将大面积污染周围海洋环境。
: 6.堆芯防护壳:保护堆芯和核燃料的一级保护壳并未爆炸,目前的辐射来源于一级保护壳少量泄漏和二级保护壳中的旧燃料(spent fuel)泄漏,旧燃料存储于一级防护壳外二级防护壳内;由于旧燃料的辐射水平有限,因此目前来看核辐射污染并不严重。当然如果堆芯防护壳破坏,那么情况就非常严重了。现在看来发生这个情况的概率不是很大。

i***a
发帖数: 195
13
1.
3月16号消息: 燃料棒已发生破损,堆芯内水位得到控制。3月15号消息:2号堆芯防护壳因爆炸已破损了造成大量核辐射, 因此750工人撤离,还有50名工人留下继续往1,2,3号堆芯灌水。
Seventy percent of the fuel rods Unit 1 and one-third in Unit 2 have been damaged, TEPCO said. The cooling water level in both units is being maintained.
2.
我说的一回路水就是和反应堆燃料棒接触的主回路(Inner Circulation Water)
http://en.wikipedia.org/wiki/File:Boiling_water_reactor_english
3.
这个无法确定,至少可以肯定的是工作了(或部分工作了),不可能完全不工作。
4.也有,一回路的高温水和水蒸气常年经过堆芯燃料棒,哪可能没有辐射,反应堆一级
保护壳里面所有材料都有辐射?燃料棒破损了,会造成更大的辐射。
5. 放气的目的是防止氢气在堆芯内堆积导致压力太大而爆炸,由于开个口子放走的只是少量,危害远没堆芯保护壳(参考6.)爆炸的危害大。据ANS报道,5,6号反应堆也开始放气了。
The company may remove some panels from the top of the reactor containment buildings at reactors 5 and 6 in order to avert a possible buildup of hydrogen in the reactors. Hydrogen buildup caused explosions at reactors 1 and 3.
6.保护堆芯的外壳(如示意图中的1)
http://en.wikipedia.org/wiki/File:Boiling_water_reactor_english
参考:
1).
http://ansnuclearcafe.org/
2).
http://en.wikipedia.org/wiki/Boiling_Water_Reactor

【在 j******h 的大作中提到】
:
: 地步
: 1.燃料棒已经出现破损,下一步就是融化如果水位下降得厉害的话,现在没人灌水放气
: ,弄不好把压力壳整个掀了都有可能。最后一步就是烧熔穿底,这个没学过,也不敢想
: 象。另外核废料污染了空气后降雨不就到地表了?水循环系统污染的后果。。。
: 2.沸水堆只有一个回路,冷却回路不算的。
: 3.可能没完全到位
: 4.燃料棒没破是不会有裂变产物泄漏到压力壳的。
: 5.你放蒸汽不一样是回到环境里,有什么区别?
: 6.请你说明什么是一级防护壳,是指燃料棒外壳还是?

b*****e
发帖数: 5476
14
spent fuel pool没有保护壳,就是个普通厂房,4号的已经塌了,而且也不是少量
你推崇的ANS网站上是这么写的
Some countries have tried to limit the number of spent fuel rods that accumulate at nuclear power plants — Germany stores them in costly casks, for example, while Chinese nuclear reactors send them to a desert storage compound in western China’s Gansu province. But Japan, like the United States, has kept ever larger numbers of spent fuel rods in temporary storage pools at the power plants, where they can be guarded with the same security provided for the power plant.
Figures provided by Tokyo Electric Power on Thursday show that most of the dangerous uranium at the power plant is actually in the spent fuel rods, not the reactor cores themselves. The electric utility said that a total of 11,195 spent fuel rod assemblies were stored at the site.
That is in addition to 400 to 600 fuel rod assemblies that had been in active service in each of the three troubled reactors. In other words, the vast majority of the fuel assemblies at the troubled reactors are in the storage pools, not the reactors.
1 (共1页)
进入Military2版参与讨论
相关主题
融芯之后,控制棒还能有效地终止裂变反应吗NHK NEWS(3/26):东电现在宣布被迫排水zz
日本核事故辟谣2NHK NEWS(3/27):2号核岛反应堆积水辐射超标1000万倍zz
是不是熔化后反应就停不住了???转贴一篇文章:全太平洋国家替他们买单 (转载)
朴抱一的博客:为什么不用担心日本的核电站Re: 转贴一篇文章:全太平洋国家替他们买单 (转载)
造谣的或者辟谣的都看过来,日本核事故更新根据鬼子此次事故谈谈原因以及沸水堆和压水堆的区别
这么多人瞎担心核泄漏,科普一下吧日本核事故辟谣
问个反应堆的问题URGENT: Fuel rods damage at Fukushima's 2 reactors estimated at 70%, 33%
Huge blast at Japan nuclear power plant zz万能的买买提 有没有这次和田暴乱的照片? (转载)
相关话题的讨论汇总
话题: 堆芯话题: fuel话题: reactors话题: 燃料话题: 防护